Document information

Title ERC/REC 70-03
Earlier (revised) version
[05-10-2018]   [08-02-2019]   [07-06-2019]   [12-06-2020]   [23-10-2020]   [12-02-2021]   [18-06-2021]   [08-10-2021]   [05-11-2021]   [11-02-2022]   [10-06-2022]   [14-10-2022]   [17-02-2023]   [16-06-2023]   [08-03-2024]  
Published Date 07-06-2024
Status Active
Description ERC/REC 70-03 of 6 October 1997 on relating to the use of Short Range Devices (SRD)

latest amended on 7 June 2024 (FM #107)
Comments The document is up-to-date generated in the EFIS database. The latest version of the national implementation status can only be found in the EFIS database and national implementation is in Appendix 1 as well as national restrictions in Appendix 3.

Older editions from 1997 to 2018 of ERC Recommendation 70-03 are to be found under attachments.

If frequency ranges and applications has no ETSI Harmonised standard linked to it, it means that the ETSI Harmonised standards are still under development.
Files
Attachments
Frequency Ranges
From To Unit Application Standard
10 9000 Hz Inductive applications EN 303 348
9 315 kHz Active medical implants EN 302 195
9 30000 kHz Inductive applications EN 300 330
9 148.5 kHz Inductive applications EN 303 447
9 148.5 kHz Inductive applications EN 303 454
9 130000 kHz NMR
148.5 5000 kHz Inductive applications
456.9 457.1 kHz Emergency detection EN 300 718
11.1 16 MHz Railway applications EN 302 609
13553 13567 kHz Non-specific SRDs EN 300 330
26990 27000 kHz Non-specific SRDs EN 300 220
26990 27000 kHz Model control EN 300 220
27040 27050 kHz Model control EN 300 220
27040 27050 kHz Non-specific SRDs EN 300 220
27090 27100 kHz Railway applications EN 302 608
27090 27100 kHz Non-specific SRDs EN 300 220
27090 27100 kHz Model control EN 300 220
27140 27150 kHz Non-specific SRDs EN 300 220
27140 27150 kHz Model control EN 300 220
27190 27200 kHz Model control EN 300 220
29.7 47 MHz Radio microphones and ALD EN 300 422
30 37.5 MHz Active medical implants EN 302 510
30 12400 MHz GPR/WPR EN 302 066
34.995 35.225 MHz Model control EN 300 220
40.66 40.7 MHz Model control EN 300 220
40.66 40.7 MHz Non-specific SRDs EN 300 220
87.5 108 MHz Wireless audio/multimedia EN 301 357
138.2 138.45 MHz Non-specific SRDs EN 300 220
169.4 174 MHz Aids for hearing impaired EN 300 422
169.4 169.8125 MHz Meter reading EN 300 220
169.4 169.8125 MHz Non-specific SRDs EN 300 220
169.8125 223 MHz Radio microphones and ALD EN 300 422
402 405 MHz Active medical implants EN 301 839
430 440 MHz ULP-WMCE EN 303 520
433.05 434.79 MHz Non-specific SRDs EN 300 220
470 862 MHz Radio microphones and ALD EN 300 422
862 870 MHz Alarms EN 300 220
862 870 MHz Non-specific SRDs EN 300 220
862 870 MHz RFID EN 302 208
862 870 MHz Tracking, tracing and data acquisition
862 870 MHz Wideband data transmission systems
863 865 MHz Radio microphones and ALD EN 300 422
863 865 MHz Radio microphones and ALD EN 301 357
870 876 MHz Non-specific SRDs EN 300 220
870 876 MHz Tracking, tracing and data acquisition EN 303 204
915 919.4 MHz Non-specific SRDs EN 300 220
915 921 MHz RFID EN 302 208
915 919.4 MHz Tracking, tracing and data acquisition
1350 1400 MHz Radio microphones and ALD EN 300 422
1492 1525 MHz Radio microphones and ALD EN 300 422
1626.5 1660.5 MHz ALS EN 300 422
1785 1805 MHz Radio microphones and ALD EN 300 422
2400 2483.5 MHz Non-specific SRDs EN 300 440
2400 2483.5 MHz RFID EN 300 440
2400 2483.5 MHz Radiodetermination applications EN 300 440
2483.5 2500 MHz Active medical implants EN 301 559
2483.5 2500 MHz MBANS EN 303 203
3100 4800 MHz UWB applications EN 302 065
4500 7000 MHz Radiodetermination applications EN 302 372
5725 5875 MHz Non-specific SRDs EN 300 440
5725 5830 MHz TTT EN 300 674
5725 5925 MHz WIA EN 303 258
5925 6700 MHz Radiodetermination applications EN 302 729
5945 6425 MHz RLAN EN 303 687
6000 9000 MHz UWB applications EN 302 065
6700 8500 MHz Radiodetermination applications EN 302 729
8500 10600 MHz Radiodetermination applications EN 302 372
9200 10000 MHz Radiodetermination applications EN 300 440
10.5 10.6 GHz Radiodetermination applications EN 300 440
13.4 14 GHz Radiodetermination applications EN 300 440
17.1 17.3 GHz GBSAR EN 300 440
24 24.25 GHz Non-specific SRDs EN 300 440
24.05 27 GHz Radiodetermination applications EN 302 372
24.05 26.5 GHz Radiodetermination applications EN 302 729
24.05 24.25 GHz TTT EN 302 858
24.25 26.65 GHz SRR EN 302 288
57 64 GHz Non-specific SRDs EN 305 550
57 64 GHz Radiodetermination applications EN 302 372
57 64 GHz Radiodetermination applications EN 302 729
57 71 GHz Wideband data transmission systems EN 302 567
75 85 GHz Radiodetermination applications EN 302 372
75 85 GHz Radiodetermination applications EN 302 729
76 77 GHz Railway applications EN 301 091
76 77 GHz TTT EN 301 091
76 77 GHz TTT EN 303 360
116 260 GHz Radio microphones and ALD EN 305 550
122 123 GHz Non-specific SRDs EN 305 550
244 246 GHz Non-specific SRDs EN 305 550
Links

Related Documents

Web Links