Document information

Title EN 300 220
Description Part 1: Technical characteristics and methods of measurement (ETSI EN 300 220-1 V3.1.1 (2017-02)

Part 2: Harmonised Standard for access to radio spectrum for non specific radio equipment (ETSI EN 300 220-2 V1.3.1 (2000-09) - new version is pending for approval (January 2025))

Part 3-1: Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Low duty cycle high reliability equipment, social alarms equipment operating on designated frequencies (869,200 MHz to 869,250 MHz) (ETSI EN 300 220-3-1 V2.1.1 (2016-12))

Part 3-2: Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Wireless alarms operating in designated LDC/HR frequency bands 868,60 MHz to 868,70 MHz, 869,25 MHz to 869,40 MHz, 869,65 MHz to 869,70 MHz (ETSI EN 300 220-3-2 V1.1.1 (2017-02))

Part 4: Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Metering devices operating in designated band 169,400 MHz to 169,475 MHz (ETSI EN 300 220-4 V1.1.1 (2017-02))
Comments
Frequency Ranges
From To Unit Application Standard
26350 27500 kHz Non-specific SRDs EN 300 220
26990 27000 kHz Model control EN 300 220
27040 27050 kHz Model control EN 300 220
27090 27100 kHz Model control EN 300 220
27140 27150 kHz Model control EN 300 220
27190 27200 kHz Model control EN 300 220
34.995 35.225 MHz Model control EN 300 220
40.66 40.7 MHz Model control EN 300 220
40.66 40.7 MHz Non-specific SRDs EN 300 220
138 143.6 MHz Non-specific SRDs EN 300 220
169.4 169.8125 MHz Meter reading EN 300 220
169.4 169.8125 MHz Non-specific SRDs EN 300 220
433.05 434.79 MHz Non-specific SRDs EN 300 220
862 870 MHz Alarms EN 300 220
862 870 MHz Non-specific SRDs EN 300 220
870 876 MHz Non-specific SRDs EN 300 220
915 921 MHz Non-specific SRDs EN 300 220
Web Links